Displaying items by tag: Nitrogen

Vertical vs Horizontal Furnaces: The Dumas Method for Protein Determination

The Dumas method has several advantages over the Kjeldahl method: it is much faster, with much lower operating costs, no real safety issues, and no toxic waste produced. However, there is a debate over which of the two main approaches to the Dumas method is better: a vertical or a horizontal combustion furnace. Determined to settle the question on which method is more precise and offers the most advantages, LECO chemists analyzed many sample types in both an FP828 and an FP928.

LECOs Lösungen für Ihre Dumas- und CHNS-Analyse

 

Wollen Sie Ihre Dumas-Analyse revolutionieren?

Dann brauchen Sie die richtige Lösung.

Durch die Integration modernster Hardware und unserer Touchscreen-Softwareplattform können Sie mit der 828 SERIE oder 928 SERIE eine Vielzahl von Probenanalysen erledigen. Die Vorteile und Leistungsmerkmale früherer Generationen von LECO Makro-Verbrennungsgeräten wurden beibehalten, während Durchsatz, Verfügbarkeit und Zuverlässigkeit entscheidend verbessert wurden. Alle Modelle der Serie 828 sind mit dem S832-Add-on kompatibel und ermöglichen eine separate Schwefelbestimmung. Makroprobenanalytik und Zykluszeiten von nur 2,8 Minuten machen die 828-Serie und 928-Serie zur idealen Lösung für eine Vielzahl von Anwendungen und bieten einen beispiellos hohen Probendurchsatz. Die unerreichten Makro-Fähigkeiten der 928 Serien mit den großen Verbrennungsschiffchen für feste und flüssige Proben stehen ebenso zur Verfügung.

 


 

 


 

Sie möchten einen Dumas-Analysator, der …

 

dumas-analysator-1

... von 20 Servicetechnikern unterstützt wird, allein im Raum DACH/Benelux.

 
dumas-analysator-10

... eine korrekte Schwefelanalytik durch Hochtemperatur-Verbrennung liefert, auch mit 100% Recoveryrate.

 
dumas-analysator-4

... eine Reduktionschemikalien-Standzeit bis zu 4.000 Analysen hat, völlig egal was Sie analysieren.

 
dumas-analysator-2

... günstigste, laufende Kosten bei geringstem Wartungsaufwand bietet.

 
dumas-analysator-9

... eine kompromisslose Verbrennung in reinem O2 bietet ohne jede Matrix Abhängigkeit und weitere Infos über die Probe.

 
dumas-analysator-3

... schnelle Analysenzeiten bietet und auch im CHN / CHNS Modus nur ca. 5 Minuten benötigt.

 
dumas-analysator-7

... einen niedrigen Helium- / Argon-Verbrauch hat (1 Flasche ≈ 5.000 Analysen).

 
dumas-analysator-5

... Flüssigkeiten einfach ohne Zusatzmaterialien einwiegen kann.

 
dumas-analysator-12

... kleine Kapseln, Folien und Gelkapseln sowie großvolumige Verbrennungstiegel flexibel verwenden kann (CHNS828).

 
dumas-analysator-11

... ein traditionelles System mit Kapseln / Folien nutzt und eines mit großvolumigen Verbrennungsschiffchen (CNS928).

 
dumas-analysator-6

... die Trocknung der Gase mit einem hocheffizienten Thermokühler durchführt ohne weiteres Trägergas. Gilt nicht für H- und S-Varianten sowie CNS928.

 

 


 

CNS928 CHN828 S832 Add on

CHNS828 & CNS928 Serie – Vorteile und Merkmale

  • Unerreichter Probendurchsatz optimiert Laborproduktivität
  • Kurze Zykluszeiten von nur 2,8 Minuten für höchste Produktivität der FP/CN-Modelle
  • Längere Lebensdauer der Reagenzien für eine optimale Betriebszeit des Geräts
  • Einfacher Zugang zu üblichen Wartungsarbeiten reduziert deutlich Standzeiten und Dauer routinemäßiger Wartungsarbeiten
  • Ergonomisches, bedienerzentriertes Design mit frei schwenkbarem Touchscreen
  • Widerstandsfähiger Autoloader für 30 Proben mit optionaler Erweiterung auf 120 Proben maximiert die Laboreffizienz
  • Verbesserte Ofeneffizienz und Zuverlässigkeit dank reagenzienfreiem Design

MEHR INFOS ZUM CHNS828 ...
MEHR INFOS ZUM CNS928 ...

 


 

Kontaktieren Sie uns

ÜBERZEUGEN SIE SICH VON DER QUALITÄT UNSERER PRODUKTE

Lassen Sie sich von den LECO Experten unsere Produkte demonstrieren und testen Sie deren Leistungsfähigkeit! Kostenlos und wenn Sie wünschen auch kontaktlos bieten wir Ihnen dafür verschiedene Services an. Buchen Sie z. B. Ihr Ticket für unsere Virtual Trade Show oder vereinbaren Sie einen Termin für eine Online-Demo.

WWW.LECO.SHOW

TICKETS for the leco.show

FP828 | Determination of Nitrogen/Protein in Soybean Meal

CN828 | Determination of Carbon and Nitrogen in Plant Tissue

CN828 | Determination of Carbon and Nitrogen/Protein in Flour

CN828 | Determination of Carbon and Nitrogen in Soil

CHN828 | Determination of Carbon, Hydrogen and Nitrogen in Coke

FP828 | Determination of Nitrogen/Protein in Milk and Milk Products

FP928 | Determination of Nitrogen/Protein in Meat and Meat Products

FP828 | Determination of Nitrogen/Protein in Feeds, Grains, and Pet Food

Accommodate Lower-Level Nitrogen Samples in Food Materials with an Optimised Combustion Method

Low-Level Nitrogen Samples in Food Materials

Did you catch our recent article on Food Navigator? Nitrogen content in food materials is necessary to measure when determining the total protein content. This measurement of nitrogen content can be performed using a classical wet chemistry method, but this tends to be a slow and tedious process. The combustion-based Dumas method has gained popularity in recent years as it significantly increases laboratory productivity. Yet when the sample has a low level of nitrogen it can be challenging to analyse. Examples of these hard-to-analyse samples include dry corn starch, NDIN filter bags, nutritional drinks, and beer. How can the combustion method be optimised to accommodate these lower-level nitrogen samples?

LECO Solutions for Inorganic Materials

LECO Solutions for Inorganic Material

From raw materials till finished products, different industries trust LECO rapid and accurate analysers measuring quality and strength on every step of materials transformation process. Learn more about Carbon and Sulfur Analysis by Combustion with the LECO CS744 and CS844, Oxygen/Nitrogen/Hydrogen Detection with the ONH836, Oxygen/Nitrogen determination by Inert Gas Fusion with the ON736, and multi-phase Carbon and Water determination with the RC612.

CHN828 | Determination of Carbon, Hydrogen and Nitrogen in Coal

ONH836 | Oxygen, Nitrogen, and Hydrogen in Refractory Metals

ONH836 | Oxygen, Nitrogen, and Hydrogen in Iron, Steel, Nickel-Base, and Cobalt-Base Alloys

ON736 | Oxygen and Nitrogen Determination in Refractory Metals and Their Alloys

Tagged under

CHN628 | Carbon, Hydrogen, and Nitrogen in Hydrocarbons

CHN628 | Carbon, Hydrogen, and Nitrogen in Coke

CHN628 | Carbon, Hydrogen, and Nitrogen in Coal

CHN628 | Determination of Carbon, Hydrogen, and Nitrogen in Biomass

928 Series | Determination of Nitrogen in Fertilizer

ONH836 | Determination of Oxygen, Nitrogen, and Hydrogen in Iron, Steel, Nickel-base, and Cobalt-base Alloys Comparison

ONH836 | Determination of Oxygen, Nitrogen, and Hydrogen in Iron, Steel, Nickel-base, and Cobalt-base Alloys Optimization

Balanced Soil: Carbon, Nitrogen, and Sulfur Determination with the CNS928

Well-balanced crops require well-balanced soil. While carbon may be the most essential element for organic life, the right ratio of nitrogen and sulfur in the soil along with the carbon can really influence the speed and strength of plant development and growth. With a macro combustion carbon, nitrogen, and sulfur determinator such as LECO's CNS928, those ratios can be discovered easily through fast and precise analysis.

There are countless fertilizers that can be applied to change the ratio of elements in soil, but without knowing the baseline for your soil, you have no practical way of knowing what it needs. LECO's CNS928 can take some of the uncertainty out of soil management.

While helium remains the inert gas of choice for elemental analysis, supply is limited, driving cost up. The CNS928 is designed to support the use of either helium or argon as a carrier gas. The thermal conductivity difference between argon and nitrogen is not as great as the thermal conductivity difference between helium and nitrogen, so the detector is inherently less sensitive when using argon for nitrogen determination, but the CNS928 does offer the option of using a larger 10 cm3 aliquot loop. The 10 cm3 aliquot loop helps to overcome the lower sensitivity of argon carrier gas by optimizing the system for the lowest nitrogen range and provides the best precision.

To see how the CNS928 handles carbon, nitrogen, and sulfur determination with various combinations of carrier gases and aliquot loop sizes, read the app note.

ON736 | Oxygen and Nitrogen in Solid Iron, Steel, Nickel-Base, and Cobalt-Base Alloys

CNS928 | Determination of Carbon, Nitrogen and Sulfur in Soil

CNS928 | Determination of Carbon, Nitrogen and Sulfur in Plant Tissue

CN928 | Determination of Carbon / Nitrogen in Soils and Plant Tissue

TC600/TCH600 | Oxygen and Nitrogen Determination in Ferroalloys

FP928 | Determination of Nitrogen/Protein in Flour

Tagged under

FP828 | Determination of Nitrogen/Protein in Flour

Tagged under