The Dumas method has several advantages over the Kjeldahl method: it is much faster, with much lower operating costs, no real safety issues, and no toxic waste produced. However, there is a debate over which of the two main approaches to the Dumas method is better: a vertical or a horizontal combustion furnace. Determined to settle the question on which method is more precise and offers the most advantages, LECO chemists analyzed many sample types in both an FP828 and an FP928.

For more information and a detailed breakdown of the results and a look at more of the samples used in this experiment, read Michael Jakob's article in the September 2021 issue of eFOOD-Lab International.

Read the Article!

 

Wollen Sie Ihre Dumas-Analyse revolutionieren?

Dann brauchen Sie die richtige Lösung.

Durch die Integration modernster Hardware und unserer Touchscreen-Softwareplattform können Sie mit der 828 SERIE oder 928 SERIE eine Vielzahl von Probenanalysen erledigen. Die Vorteile und Leistungsmerkmale früherer Generationen von LECO Makro-Verbrennungsgeräten wurden beibehalten, während Durchsatz, Verfügbarkeit und Zuverlässigkeit entscheidend verbessert wurden. Alle Modelle der Serie 828 sind mit dem S832-Add-on kompatibel und ermöglichen eine separate Schwefelbestimmung. Makroprobenanalytik und Zykluszeiten von nur 2,8 Minuten machen die 828-Serie und 928-Serie zur idealen Lösung für eine Vielzahl von Anwendungen und bieten einen beispiellos hohen Probendurchsatz. Die unerreichten Makro-Fähigkeiten der 928 Serien mit den großen Verbrennungsschiffchen für feste und flüssige Proben stehen ebenso zur Verfügung.

 


 

 


 

Sie möchten einen Dumas-Analysator, der …

 

dumas-analysator-1

... von 20 Servicetechnikern unterstützt wird, allein im Raum DACH/Benelux.

 
dumas-analysator-10

... eine korrekte Schwefelanalytik durch Hochtemperatur-Verbrennung liefert, auch mit 100% Recoveryrate.

 
dumas-analysator-4

... eine Reduktionschemikalien-Standzeit bis zu 4.000 Analysen hat, völlig egal was Sie analysieren.

 
dumas-analysator-2

... günstigste, laufende Kosten bei geringstem Wartungsaufwand bietet.

 
dumas-analysator-9

... eine kompromisslose Verbrennung in reinem O2 bietet ohne jede Matrix Abhängigkeit und weitere Infos über die Probe.

 
dumas-analysator-3

... schnelle Analysenzeiten bietet und auch im CHN / CHNS Modus nur ca. 5 Minuten benötigt.

 
dumas-analysator-7

... einen niedrigen Helium- / Argon-Verbrauch hat (1 Flasche ≈ 5.000 Analysen).

 
dumas-analysator-5

... Flüssigkeiten einfach ohne Zusatzmaterialien einwiegen kann.

 
dumas-analysator-12

... kleine Kapseln, Folien und Gelkapseln sowie großvolumige Verbrennungstiegel flexibel verwenden kann (CHNS828).

 
dumas-analysator-11

... ein traditionelles System mit Kapseln / Folien nutzt und eines mit großvolumigen Verbrennungsschiffchen (CNS928).

 
dumas-analysator-6

... die Trocknung der Gase mit einem hocheffizienten Thermokühler durchführt ohne weiteres Trägergas. Gilt nicht für H- und S-Varianten sowie CNS928.

 

 


 

CNS928 CHN828 S832 Add on

CHNS828 & CNS928 Serie – Vorteile und Merkmale

  • Unerreichter Probendurchsatz optimiert Laborproduktivität
  • Kurze Zykluszeiten von nur 2,8 Minuten für höchste Produktivität der FP/CN-Modelle
  • Längere Lebensdauer der Reagenzien für eine optimale Betriebszeit des Geräts
  • Einfacher Zugang zu üblichen Wartungsarbeiten reduziert deutlich Standzeiten und Dauer routinemäßiger Wartungsarbeiten
  • Ergonomisches, bedienerzentriertes Design mit frei schwenkbarem Touchscreen
  • Widerstandsfähiger Autoloader für 30 Proben mit optionaler Erweiterung auf 120 Proben maximiert die Laboreffizienz
  • Verbesserte Ofeneffizienz und Zuverlässigkeit dank reagenzienfreiem Design

MEHR INFOS ZUM CHNS828 ...
MEHR INFOS ZUM CNS928 ...

 


 

Kontaktieren Sie uns

ÜBERZEUGEN SIE SICH VON DER QUALITÄT UNSERER PRODUKTE

Lassen Sie sich von den LECO Experten unsere Produkte demonstrieren und testen Sie deren Leistungsfähigkeit! Kostenlos und wenn Sie wünschen auch kontaktlos bieten wir Ihnen dafür verschiedene Services an. Buchen Sie z. B. Ihr Ticket für unsere Virtual Trade Show oder vereinbaren Sie einen Termin für eine Online-Demo.

WWW.LECO.SHOW

TICKETS for the leco.show

Kent Scientific Services

"Moisture analysis is typically a classical gravimetric technique when analysing both food and animal feeds. As such there is a considerable amount of 'hands on' analyst time to ensure accuracy. Freeing up analyst time allowing focus on other testing was the drive and automation of tests such as moisture was key to achieving.

The laboratory was aware of systems on the market which it could use to automate the moisture analysis but dealing with companies with a trusted track record, allowing an easier route to commission any such testing, was very important under our accreditation. We have used LECO instrumentation for nitrogen testing for over 20 years and therefore we felt that initial discussion with the company was justified. The instrumentation was then purchased on time and on budget. Communication with the representatives and technical specialists during the purchase was excellent.

We have had a long association with using LECO instrumentation particularly in the field of nitrogen/protein testing and they are viewed as a leader in this field. Reliability and accuracy of equipment is very important in the enforcement field and our experience is that LECO instrumentation delivers on both. The instrumentation (TGM) purchased was also at an affordable cost which ticked another box for us.
Time savings have been made as the analyst only has to weight the samples and set the instrumentation going and the rest is automated. Checking that the weighings are 'true' and to constant weight is the next intervention but this is clear from the analytical printout and takes little time and effort. So the time process of moisture determinations has now been optimised and we are achieving good external proficiency test results enhancing confidence in the figures reported to customers.

The equipment is robust, accurate and well priced compared to others on the market. LECO are a well established company with a long track record to producing high quality and reliable instrumentation. We are over cautious in terms of our suppliers of instrumentation in terms of the legal implications of the samples we are testing and the constraints of the ISO 17025 accreditation we work to. But LECO instrumentation we have used has never failed to deliver. Excellent after sales care is another bonus and engineers and reps are easily accessible."

Microplastics: Seeing the Details with GC×GC

Microplastics are a ubiquitous presence in the world, found from Arctic snow to Antarctic ice and everywhere in between. There are trillions of microplastic particles floating on surface water, and everyone from infants to adults are presumed to be ingesting anywhere from dozens to tens of thousands of these particles every day.

 Video: LECO Advance MOSH / MOAH Analyser // On Demand

Now available as an on-demand video!

Watch LECO's Advanced MOSH / MOAH Analyser in action!

The TGA: Macro and Micro

Thermogravimetric analysis (TGA) first started in the early 20th century, and while the technology has advanced, the basic principles remain the same. With TGA, the rate of change of reactions in the chemical and physical properties of materials as functions of temperature or time is what is used to assess the properties of the sample materials. Most TGA these days is done with either micro TGAs (using milligram-size samples) or macro TGAs (using gram-size samples).

Folded Flight Path®: Ten Years of High Resolution

The first Time-of-Flight (TOF) mass spectrometer was proposed in 1946, and the design has been refined and iterated upon every since.
With an unlimited mass range visible in each spectrum and a high spectral generation speed, the advantages of TOF mass spectrometry were immediately clear. Though the instruments improved, they did eventually hit physical limitations that restricted the resolving power. More work had to be done.